property
OBJECT
address
1234 Palm Harbor Drive, Tampa, FL 33615string
yearBuilt
2006integer
squareFeet
2,847integer
constructionType
CBS / Concrete Blockstring
stories
2integer
floodZone
X (Minimal Risk)string
buildingCode
2005 Florida Building Codestring
propertyScore
87 / 100integer
systems
ARRAY[4]
systems[0] - Roof
PASS
material
GAF Timberline HDZ Architectural Shingle
yearInstalled
2018
remainingLifeYears
17-22
deckAttachment
B - Dimensional Lumber (8d nails, 6" o.c.)
roofToWall
Clips (Simpson H2.5A)
geometry
Hip - 100%
swr
false
permitNumber
BP-2018-04523
permitVerified
true
systems[1] - Electrical
PASS
panelType
200A Main Breaker - Square D (Schneider)
wiringType
Copper (Romex NM-B)
gfciProtection
true - All required locations
afciProtection
true - Bedrooms (NEC 2017)
yearUpgraded
2014
systems[2] - Plumbing
FAIR
supplyPiping
Copper (original) + PEX (partial 2020)
drainPiping
PVC / ABS
waterHeater
A.O. Smith 50-gal Electric (2021)
condition
Aging copper fittings - recommend monitoring
systems[3] - HVAC
PASS
systemType
Central Split - Heat Pump
manufacturer
Carrier Infinity 3.5T / 16 SEER
yearInstalled
2021
lastServiced
2025-10-15
riskAssessment
OBJECT
overallRisk
LOW
propertyScore
87
structuralRisk
LOW
windStormRisk
LOW
fireElectricalRisk
LOW
waterPlumbingRisk
MODERATE
aiConfidence
0.92
windMitigation
✓ VERIFIED
fbcCompliant
true
roofDeckAttachment
B
roofToWallConnection
Clips
roofGeometry
Hip (100%)
secondaryWaterResistance
false
openingProtection
A - All Openings Protected
estimatedDiscountPct
45
findings
ARRAY[4]
[0]
Plumbing re-pipe · urgency: SOON · cost: $4,200-$6,800 · system: Plumbing
[1]
SWR installation · urgency: PLANNED · cost: $1,800-$2,500 · system: Roof
[2]
Copper fitting monitor · urgency: MONITOR · cost: Included · system: Plumbing
[3]
GFCI cover replace · urgency: MINOR · cost: $15-$25 · system: Electrical
attachedDocuments
ARRAY[5]
[0]
Four-Point Inspection Report · type: PDF · pages: 12 · verified: true
[1]
Wind Mitigation Report · type: PDF · pages: 14 · verified: true
[2]
Full Home Inspection · type: PDF · pages: 42 · verified: true
[3]
Photo Collection · type: JPEG · count: 47 · geoTagged: true
[4]
Verified Property Record (VPR) · type: PDF · pages: 3 · qrVerified: true
◆ Integration Note for Carriers
This structured data export is available via the Vcita API and direct platform download. It replaces the need to manually extract information from PDF reports. All data fields are validated against the original inspection and permit records. Contact Vcita to set up automated carrier integration with your underwriting system.
GET /api/v2/exports/{inspectionId}/carrier · Content-Type: application/json