Vcita Home Inspection & Service LLC

Serving All of Florida
4-Point Inspection Report
Citizens Property Insurance Corporation • Insp4pt 03/25
Subject Property
1247 Royal Palm Blvd
Vero Beach, FL 32960 • Indian River County
Insured / Applicant
Carlos & Maria Rivera
Policy / Application #
CIT-FL-2026-487291
Inspection Date
April 15, 2026
Year Built
2004
Report ID
4PT-2026-SAMPLE-001 • v1
Status
COMPLETED
Inspected By
Calvin S. Johnson
Home Inspector • FL License #HI2622
Vcita Home Inspection & Service LLC
772.224.5655 • [email protected]
Confidential • For Insurance Underwriting Purposes Only
Vcita Home Inspection & Service LLC
Licensed Florida Home Inspector • 772.224.5655
October 18, 2026
Transmittal Letter - 4-Point Inspection

To the Underwriter / Carrier of Record:

Please find attached the completed Citizens Property Insurance Corporation 4-Point Inspection Form (Insp4pt 03/25) for the property referenced below, performed on April 15, 2026.

Applicant / Insured:Carlos & Maria Rivera
Subject Property:1247 Royal Palm Blvd, Vero Beach, FL 32960
Year Built:2004
Inspection Date:April 15, 2026
Report ID:4PT-2026-SAMPLE-001
Overall Underwriting Verdict:MEETS UNDERWRITING CRITERIA

This inspection was conducted in compliance with the Citizens Insp4pt 03/25 form and the carrier-specific underwriting standards adopted by the major Florida residential insurance markets. The scope of review covered the four principal building systems: Roof, Electrical, Plumbing, and HVAC. Observations were visual and non-invasive, and are supported by the photographs in the Photographic Evidence section of this report.

Key systems were assessed against the following criteria:

Any items that did not meet the criteria are summarized on the Findings & Punch-List page (and, where applicable, the Hazards & Non-Conformities page); the underlying observations remain in their original Citizens form section.

Should you require clarification on any field, additional imagery, or a re-inspection after remediation, please contact me directly.

Respectfully submitted,

Calvin S. Johnson
Home Inspector • FL License #HI2622
Vcita Home Inspection & Service LLC
772.224.5655  •  [email protected]

Table of Contents

Use this index to navigate the report. Section numbers follow the required Citizens Insp4pt 03/25 order.
1. Cover
2. Transmittal Letter - Underwriter
3. Table of Contents
4. Compliance Dashboard
Advisory Insights
5. Systems Snapshot & Remaining Useful Life
Citizens Form - Insp4pt 03/25
6. I. Electrical System
7. II. HVAC System
8. III. Plumbing System
9. IV. Roof & Inspector Certification
10. Component Inventory Summary
Advisory Insights & Agent Summary
11. Findings, Recommendations & Punch-List
12. Deal Confidence Summary
Photographic Evidence
▸ Organized by system (5 groups)
Appendix
▸ Reference Diagrams
▸ Methodology & Standards
▸ Inspector Signature - Back Cover

4-Point Compliance Dashboard

An at-a-glance summary of the four principal building systems evaluated against insurance underwriting criteria.
Overall Underwriting Verdict
MEETS UNDERWRITING CRITERIA
🏠
Roof
PASS
CoveringAsphalt / Fiberglass Shingle
Age7 yrs
Remaining Life15+ years yrs
⚡
Electrical
PASS
PanelCircuit Breaker - Square D (QO Series)
Service200 Amps
WiringCopper
🔧
Plumbing
PASS
SupplyCopper
DrainPVC
Water Heater6 yrs old
AdvisoryMonitor (age)
❄️
HVAC
PASS
SystemCentral A/C with Heat Pump
ManufacturerTrane
Age5 yrs
0 of 11
Required Photo Items (10 photos on file)
0
Hazard Flags
4 of 4
Systems Inspected
Insp4pt 03/25
Form Version
Verdict Legend - PASS meets underwriting criteria; REVIEW requires carrier review; FAIL does not currently meet criteria.
Advisory Overview — complements the compliance dashboard

Systems Snapshot & Remaining Useful Life

Each principal system is shown with its present condition and an estimated remaining service life based on typical industry age benchmarks. MONITOR means the system meets criteria today but is approaching its typical age benchmark.
🏠Roof
PASS
Asphalt / Fiberglass Shingle • 7 yrs old • Condition Satisfactory
Remaining Useful Life~15 of 22 yrs
Within typical service life for the covering type.
⚡Electrical
PASS
Square D (QO Series) Circuit Breaker • 200 Amps • Copper wiring
Remaining Useful Life~13 of 35 yrs
Hazard noted: None observed — see electrical section.
🚰Plumbing
MONITOR
Copper supply / PVC drain • Water heater 6 yrs old • No active leaks
Remaining Useful Life~0 of 50 yrs
Supply piping is approaching its typical service benchmark — keep re-pipe / permit records handy.
❄️HVAC
PASS
Central A/C with Heat Pump • Trane • 5 yrs old • Condition Satisfactory
Remaining Useful Life~10 of 15 yrs
Operating within expected service life.
INSURABILITY SUMMARYFor Underwriting Use
✓ Meets underwriting criteria as of the inspection date.
No active deficiencies were observed in the four principal systems that would preclude coverage. The only age-related watch item is plumbing; the remaining systems carry ample remaining service life.
Remaining-life figures are illustrative estimates based on typical industry age benchmarks and observed condition; actual lifespan varies. Provided for discussion only — the compliance findings in this report govern.
Vcita Home Inspection & Service LLC1247 Royal Palm Blvd
Citizens Property Insurance Corporation • Form Insp4pt 03/25
I. Electrical System
Main Panel
Panel Type / Brand:Circuit Breaker - Square D (QO Series) Amperage:200 Amps
Main Panel
Panel Type / Brand:N/A Amperage:N/A
Year Installed:2004 Condition:Satisfactory
Location:Garage - east wall
Notes:Properly labeled, no double-taps, GFCI/AFCI protection present.
Wiring
Wiring Type Present: ☑ Copper    ☐ Aluminum    ☐ Knob & Tube    ☐ Romex/NM    ☐ BX/AC
Aluminum Wiring Remediation: N/A - No aluminum wiring GFCI Protection: Yes - All required locations
Grounding: Yes - Ground rod and water pipe bond visible
Hazards Present
☐ Federal Pacific / Stab-Lok    ☐ Zinsco / GTE-Sylvania    ☐ Double Tapped Breakers    ☐ Corrosion   
☐ Open Knockouts    ☐ Scorching / Melting    ☐ Improper Wiring    ☐ Other
General Condition of Electrical System: ☑ Satisfactory    ☐ Unsatisfactory
Supplemental Information - Electrical
Panel Age / Year Updated: Original Brand / Model: Square D (QO Series)
Wiring Type: Copper
Additional Comments / Observations - Electrical System
Original 2004 installation. Panel is Square D QO series, 200A. No updates needed.
Vcita Home Inspection & Service LLC1247 Royal Palm Blvd
Citizens Property Insurance Corporation • Form Insp4pt 03/25
II. HVAC System (Heating, Ventilation & Air Conditioning)
Central A/C: ☑ Yes   ☐ No Central Heat: ☑ Yes   ☐ No
System Type: Central A/C with Heat Pump Manufacturer: Trane
In Working Order? ☑ Yes   ☐ No Ductwork Condition: Good - No visible damage or disconnections
Primary System
System Type:Central A/C with Heat Pump Manufacturer:N/A
Year Installed:2021 Capacity:3.5 Ton / 16 SEER
Fuel Type:N/A Condition:Satisfactory
Location:East side (condenser) / Hallway closet (air handler) Serial #:N/A
Notes:System cycling normally. Temperature differential 18°F.
Hazards
☐ Wood-burning stove or central gas fireplace present
☐ A/C or heating not in working order
General Condition of HVAC: ☑ Satisfactory    ☐ Unsatisfactory
Supplemental Information - HVAC
Approximate Age: 5 years Year Updated: 2021
Additional Comments / Observations - HVAC System
Full HVAC replacement 2021. Trane XR16 heat pump, 3.5 ton, 16 SEER. R-410A refrigerant.
Vcita Home Inspection & Service LLC1247 Royal Palm Blvd
Citizens Property Insurance Corporation • Form Insp4pt 03/25
III. Plumbing System
TPR Valve Present & Functional? Yes Water Heater Type: Tank - Gas
Evidence of Active Leaks? ☐ Yes   ☑ No Mold / Corrosion: None
Water Heater
Type:Tank - Gas Age:6 years
Additional Water Heater (1)
Primary Water Heater: Age: Installed 2020
  Type / Fuel: N/A - 50 Gallon Condition:Satisfactory
  Location:Garage
  Notes:Elevated 18". TPR valve present with discharge pipe routed to exterior within 6" of floor.
Fixture / Component Condition
Component Satisfactory Unsatisfactory N/A
Water Heater ☑ ☐ ☐
Supply Piping ☑ ☐ ☐
Drain / Waste Piping ☑ ☐ ☐
Fixtures (sinks, toilets, etc.) ☑ ☐ ☐
General Condition of Plumbing: ☑ Satisfactory    ☐ Unsatisfactory
Supplemental Information - Plumbing
Supply Pipe Material: Copper Drain Pipe Material: PVC
Supply Piping Age: Original (2004) Drain Piping Age: Original (2004)
Water Heater Age: 6 years PEX Install Year: N/A
Additional Comments / Observations - Plumbing System
Water heater replaced 2020 (Rheem 50-gal gas). Supply and drain piping original 2004.
Vcita Home Inspection & Service LLC1247 Royal Palm Blvd
Citizens Property Insurance Corporation • Form Insp4pt 03/25
IV. Roof
Predominant Roof Secondary Roof (if applicable)
Covering Material: Asphalt / Fiberglass Shingle Covering Material: N/A
Approximate Age: 7 years Approximate Age: N/A
Remaining Useful Life: 15+ years Remaining Useful Life: N/A
Number of Layers: 1 Number of Layers: N/A
Permit Obtained? ☐ Yes   ☐ No Permit Obtained? N/A
If Updated - Full or Partial? Partial (N/A - Full replacement 2019%) If Updated - Full or Partial? N/A
Overall Condition of Roof: ☑ Satisfactory    ☐ Unsatisfactory
Damage / Deterioration Observed
☐ Excessive Granule Loss    ☐ Soft / Spongy Decking    ☐ Cracked / Broken Tiles    ☐ Rust / Corrosion   
☐ Curling / Buckling    ☐ Moss / Algae    ☐ Flashing Damage    ☐ Other
Granule loss: None
Soft decking: None
Visible Leaks? ☐ Yes   ☑ No
V. Additional Comments / Observations
This 2004 CBS-constructed home is in excellent condition for insurance underwriting purposes. All four major systems meet Citizens' requirements. The roof was fully replaced in 2019 with permit documentation on file. The HVAC is a modern high-efficiency system only 5 years old. Copper wiring and plumbing throughout. No hazards or deficiencies identified.
Inspector Certification
I certify that I have personally inspected the above referenced property and that the information contained in this report is true and accurate to the best of my knowledge and belief.
Inspector Signature
Title
Home Inspector
Inspector Name
Calvin S. Johnson
License Number
HI2622
Date
4/15/2026
Company Name
Vcita Home Inspection & Service LLC
License Type
Home Inspector
Work Phone
772.224.5655
Vcita Home Inspection & Service LLC1247 Royal Palm Blvd
Citizens Property Insurance Corporation • Form Insp4pt 03/25
Component Inventory Summary

Complete listing of all inspected building components by system category.

Electrical Panels (1)
Label Manufacturer Model Year/Age Capacity Fuel Condition Location
Main Panel — — 2004 — — Satisfactory Garage - east wall
HVAC Units (1)
Label Manufacturer Model Year/Age Capacity Fuel Condition Location
Primary System — — 2021 3.5 Ton / 16 SEER — Satisfactory East side (condenser) / Hallway closet (air handler)
Water Heaters (1)
Label Manufacturer Model Year/Age Capacity Fuel Condition Location
Primary Water Heater — — 2020 50 Gallon — Satisfactory Garage
Roof Sections (1)
Label Manufacturer Model Year/Age Capacity Fuel Condition Location
Main Roof — — 2019 — — Satisfactory —
Advisory Overview — separate from the compliance core

Findings, Recommendations & Repair Punch-List

Each system with its advisory severity and a plain-language recommendation.
SystemSeverityObservationRecommendation
Roof SATISFACTORY Asphalt / Fiberglass Shingle, approx. 7 years old with an estimated 15 years of remaining life. No active leaks observed. No action required. Continue routine maintenance.
Electrical SATISFACTORY 200 Amps Square D (QO Series) Circuit Breaker, copper wiring. Hazard: None observed. No action required. Continue routine maintenance.
Plumbing MONITOR Copper supply / PVC drain in satisfactory condition. Water heater 6 years old with TPR valve present. No active leaks or corrosion. No correction required. Monitor: supply piping is approaching its typical service benchmark; keep any re-pipe records available for the carrier.
HVAC SATISFACTORY Central A/C with Heat Pump (Trane), approx. 5 years old, operating normally at inspection. No action required. Retain installation records for warranty.
General INFO Property built 2004; systems generally well maintained for age. No deficiencies requiring correction; age-related monitoring noted for plumbing.
SATISFACTORY no action needed; MONITOR plan / budget item; ACTION correction recommended; INFO context only.
Severities reflect advisory condition assessment and remaining-life estimates. Insurance eligibility is governed by the Citizens compliance findings elsewhere in this report.
Agent-Facing Summary

Deal Confidence Summary

A plain-English summary of the four principal systems for the buyer, seller, and their agents.

3 of 4
Systems with long life left
0
Coverage-blocking defects
1
Item to budget for
What this means for your client
SCAN TO
VERIFY
Verified & tamper-evident. Every Vcita report carries a scannable verification code, inspector license, and unique Report ID — so agents and underwriters know it's authentic. Report ID 4PT-2026-SAMPLE-001.
Remaining-life figures are illustrative estimates based on typical industry age benchmarks and observed condition; actual lifespan varies. For discussion only — the compliance findings in this report govern.

Roof - Photographic Evidence

2 photos documented
Roof shingles - GAF Timberline HDZ, 2019
Roof shingles - GAF Timberline HDZ, 2019
Soffit and fascia - continuous ventilation
Soffit and fascia - continuous ventilation

Electrical - Photographic Evidence

2 photos documented
Main electrical panel - 200A Square D QO, properly labeled
Main electrical panel - 200A Square D QO, properly labeled
GFCI outlet - kitchen counter, tested functional
GFCI outlet - kitchen counter, tested functional

HVAC - Photographic Evidence

2 photos documented
Condenser unit - Trane XR16, east side
Condenser unit - Trane XR16, east side
Air handler - Trane, hallway closet
Air handler - Trane, hallway closet

Plumbing - Photographic Evidence

3 photos documented
Water heater - Rheem 50-gal, elevated, TPR present
Water heater - Rheem 50-gal, elevated, TPR present
Copper supply lines under kitchen sink
Copper supply lines under kitchen sink
Bathroom plumbing fixtures - no leaks
Bathroom plumbing fixtures - no leaks

General - Photographic Evidence

1 photo documented
Front elevation - subject property
Front elevation - subject property

Reference Diagrams

Visual reference guides for each inspected system, with insurance carrier risk-tier classifications.
Reference: Asphalt / Composition Shingle
Roof Covering Preferred
Asphalt / Composition Shingle
Standard asphalt/composition shingles - the most common roof covering in Florida. Three-tab shingles typically last 15-20 years; architectural (dimensional) shingles can last 25-30 years. Carriers require minimum 3-5 years remaining useful life.
📐 Expected life: 15-30 years depending on grade
Preferred - widely accepted, predictable lifespan
Selected: Asphalt / Fiberglass Shingle
Reference: Modern Circuit Breaker Panel
Electrical Panel Preferred
Modern Circuit Breaker Panel
Standard modern electrical panel with circuit breakers (Square D, Siemens, Eaton, GE). Individual breakers trip to protect circuits from overload. 100-200 amp service is standard for modern homes. Carriers consider this the safest panel configuration.
📐 100-200A service typical
Preferred - modern, safe, standard in all new construction
Selected: Circuit Breaker - Square D (QO Series)
Reference: Copper Wiring (NM/Romex)
Wiring Type Preferred
Copper Wiring (NM/Romex)
Copper NM (non-metallic sheathed, aka Romex) wiring is the modern standard for residential electrical systems. Excellent conductivity, corrosion resistance, and safety record. All carriers accept copper wiring without restrictions.
📐 NM-B 14/2 or 12/2 AWG typical
Preferred - industry standard, no restrictions
Selected: Copper

Reference Diagrams (continued)

Visual reference guides for each inspected system, with insurance carrier risk-tier classifications.
Reference: Copper Supply Lines
Supply Pipe Material Preferred
Copper Supply Lines
Copper supply piping is the gold standard for residential plumbing. Extremely durable (50-70 year lifespan), corrosion-resistant, and universally accepted by insurance carriers. Type M (thin wall) for supply, Type L for underground.
📐 Expected life: 50-70 years
Preferred - longest lifespan, lowest claim risk
Selected: Copper
Reference: Package Unit / Heat Pump
HVAC System Preferred
Package Unit / Heat Pump
All-in-one package unit (typically roof or ground-mounted) or heat pump system that provides both cooling and heating. Common in condos and smaller Florida homes. Heat pumps are energy-efficient and increasingly popular. 15-20 year lifespan.
📐 Expected life: 15-20 years
Preferred - efficient, carrier-accepted
Selected: Central A/C with Heat Pump

Methodology & Standards

Scope. A 4-Point inspection is a limited-scope insurance qualification inspection of the four principal building systems: Roof, Electrical, Plumbing, and HVAC. This inspection is not a home inspection and does not evaluate structural, environmental, or life-safety systems beyond the four systems listed.

Form compliance. This report is based on the Citizens Property Insurance Corporation Form Insp4pt 03/25, the current statewide reference form adopted by most Florida residential insurance carriers. All required fields, checkboxes, and photo requirements present on the official form are reproduced on the respective section pages.

Evaluation criteria. Each system was evaluated against:

Verdict classification. Each system is classified as follows:

Limitations. Observations are strictly visual and non-invasive. Items concealed by finishes, stored items, or contents are outside the scope of this inspection. This report is not a warranty or guarantee of future system performance and should not be relied upon as such. The report reflects the conditions observed on the date of inspection only.

Photographic evidence. 0 of 11 required photo items on the Citizens Insp4pt 03/25 minimum photo list are included in this report. Items marked "Not included" below were not available at the time this report was generated. Duplicate captures of the same reference image are consolidated to a single frame.

Photo requirementStatusNotes
General - Exterior Elevations Not included Front of Dwelling, Rear of Dwelling, Left Side of Dwelling, Right Side of Dwelling
Roof - Slope Coverage Not included
Roof - Material Close-Up Not included
Electrical - Main Panel (Cover On) Not included
Electrical - Main Panel (Cover Off) Not included
Plumbing - Water Heater Not included
Plumbing - TPR Valve (Insp4pt 03/25) Not included
Plumbing - Under-Cabinet Not included
Plumbing - Exposed Valves Not included
HVAC - Condenser / Outdoor Unit Not included
HVAC - Data Plate Not included
Electrical - Hazard Documentation (conditional) Not included

Confidentiality. This report is prepared for the named applicant / insured and their insurance carrier of record. It may not be used for any other purpose without written consent of the inspector of record.

Vcita Home Inspection & Service LLC
Inspector of Record
Calvin S. Johnson
Home Inspector
FL License #HI2622
Inspector signature - April 15, 2026
Vcita Home Inspection & Service LLC
772.224.5655  •  [email protected]
Serving All of Florida
Report 4PT-2026-SAMPLE-001
Confidential • Prepared for Insurance Underwriting Purposes